Historical FAQ (Frequently Asked Questions)
The plotter cuts the first characters cleanly and then begins to draw indefinable curves.
This is a typical buffer overflow problem when the plotter is driven serially. This occurs when the flow control is not properly set up for serial transmission. For serial data transmission most plotters are driven with the following parameters:
...
If the object height exceeds e.g. 70cm CoCut and EuroCUT are changing right into the segmentation dialog.
As default setting the Roland PNC 950 and 960 have their origin point at lower left. Nearly all other
...
How can I set the plotter´s origin point to the lower right position required by CoCut/EuroCUT?
Turn off the plotter and set the dip switch 6 to on. This activates the plotters Rotate function which
...
After 70cm (27.5in) the vinyl is transported back and the plot continued at the origin point.
Open the driver editor as described above, change the value for ‘framesize’ to 68cm and save the driver.
...
The output size of my graphics is more than twice as large as the original size.
The default setting for the resolution of the Mimaki CG series is 0.025mm, although they can work with
...
The plotting output is about 20% too small.
As the Gerber plotters of the HS series have a very high plotting resolution (plotting point size 0.000254
...
Although Ive activated the read back button in the cutting dialog the returned value is 0. How can I adjust my plotter so the right foil width value is returned?
The plotter has to be in the so-called host-mode. If you want to change the plotter settings, you first
...
Complete questions and answers
[