Question: Often EuroCUT is closed with the message copy protection not found while you are printing.
Answer: EuroCUT verifies the presence of the copy protection (dongle) at irregular intervals. When printing  
with the print spooler it may happen that the printing data are read back instead of the dongle  
data and thus the dongle cannot be properly detected. As EuroCUT does not verify the presence of  
the donlge during printing and the above-mentionend problems only occur when you are printing with  
the print spooler, you must turn off the print spooler. To do this, proceed as follows: click on  
the Windows 95 start button select settings/printer. Click with the right mouse button on  
the icon of the printer which is plugged in behind the dongle, select properties and then  
the details tab. Click on spool settings and choose send printing orders to  
printer
.

Note: Generally there should be a free ISA slot in your computer into which you can  
insert another parallel interface card. If you plug the dongle into this second parallel interface,  
it is possible to use the print spooler.

24.07.2001

Keywords: Dongle EuroCUT printer